Nano spectrophotometer LNS-B11 is micro volume UV spectrophotometer which takes measurements at 230 nm, 260 nm, 280 nm. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life. They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components is specially designed to analyze the concentration of pure of nucleic acid. The data can be printed with built in printer and can be transferred via SD- RAM card or USB. It requires only minimal amount of sample for accurate measurement.
Buy Now View Catalog| Cuvette | |
| Temperature | |
| PC | |
| Wavelength range | 230 nm, 260 nm, 280 nm |
| Path length | 1.0 mm, 0.2 mm |
| Wavelength accuracy | |
| Wavelength Resolution | |
| Path length of cuvette | |
| Minimum Sample size | 0.3 - 2.0 µl |
| Absorbance range | 0.2 - 75A (10 mm equivalent absorbance) |
| Precision of wavelength | |
| Absorbance precision | 0.002 Abs |
| Absorbance accuracy | 0.01 |
| Light source | Xenon flash lamp |
| Measurement time | < 5 s |
| Operating Voltage | |
| Sample Pedestal Material | |
| Detector Type | |
| Screen | |
| Software Compatibility | |
| Detects nucleic acid up to | 10 - 3750 ng/µL (dsDNA) |
| Detects protein up to | 0.5 - 110 mg/mL (BSA) |
| Data Output | |
| Operating Power Consumption | |
| Standby Power Consumption | |
| Dimension | 240 x 220 x 140 mm |
| Weight | 2.35 kg |
The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
Wavelength range : 200 - 800 nm
Path length : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy : ± 1 nm
Wavelength range : 200 - 850 nm
Path length : 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy : ± 1 nm
Wavelength range : 190 to 850 nm
Wavelength accuracy : ± 1 nm
Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
Cuvette : Yes
Temperature : 4 ºC - 42 ºC (Heating & Cooling)
PC : Inbuilt
Wavelength : 260 nm and 280 nm; Fixed
Spectral resolution : ≤ 8 nm
Path length : 0.5 mm
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Wavelength Range | 900 nm to 2500 nm |
| Wavelength Accuracy | ≤ 0.2 |
| Wavelength Reproducibility | ≤ 0.05 |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
| Working spectral range | 190 to 900 nm |
| Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength range | 190 - 900 nm |
| Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Wavelength accuracy | ≤ ± 0.5 nm |
Talk to us?